APM.MV_TYPE - APMonitor Option
Type: Integer, Input Default Value: 1 Description: Manipulated variable type 0=zero order hold 1=first order hold (linear)
MV_TYPE specifies either a zero order hold (0) or a first order linear (1) interpolation between the MV endpoints. When the MV_STEP_HOR is two or greater, the MV_TYPE is applied only to each segment where adjustments are allowed. The MV segment is otherwise equal to the prior time segment. The MV_TYPE only influences the solution when the number of NODES is between 3 and 6. It is not important when NODES=2 because there are no interpolation nodes between the endpoints.